TrueCable Cat6 UTP Riser CMR — Box 1000ft
0.714 box · materials $157.08 · labor 5.712 hr
Route 540 ft + 10% slack + 10 ft × 12 ends = 714 ft billed.
Sample
This customer, this address, and this job are fictional. It is not a bid, not a case study, and not a stamped design. In the app, Open sample quote loads the same story on your company profile and your price book.
Prepared for
Harbor & Pine Dental (SAMPLE — fictional)
Price book: Stock price book · updated 2026-09-20
One Cat6 riser line stands in for six runs, about 90 ft of route each (540 ft). Defaults are 10% slack and a 10 ft service loop at each end (12 ends).
Billed length: route 540 ft + 10% slack (54 ft) + service loops 10 ft × 12 ends (120 ft) = 714 ft billed. Order 0.714 box (714 ft).
Dollars below are the stock price book illustration at $85/hr, before markup, trip, and tax. Your book can differ. Labor hours follow that book. They are not electrical labor units.
0.714 box · materials $157.08 · labor 5.712 hr
Route 540 ft + 10% slack + 10 ft × 12 ends = 714 ft billed.
6 ea · materials $51.00 · labor 1.20 hr
6 ea · materials $14.10 · labor 0.72 hr
6 ea · materials $39.00 · labor 0.30 hr
1 ea · materials $55.00 · labor 0.60 hr
Materials $316.18 · Labor 8.532 hr · Labor $725.22 before markup, trip, and tax.
This quote includes materials and labor listed above for low-voltage cabling work only. Unless separately listed, it does not include: cable tray / ladder rack / conduit beyond noted EMT or raceway; core drilling or firestopping; permits, inspections, or engineered drawings; network electronics (switches, APs, cameras, NVRs); pathway repair, painting, or drywall patch; after-hours / weekend premium; or existing cable removal/demo. Final scope confirmed on site. Pricing valid 30 days.
Route length is the path entered on each cable run. Billed cable length is that route plus the slack percent, plus a service loop at each end (loop length times ends). This sample is six fictional drops at about 90 ft of route each, with a loop at both ends. Lengths are field estimates and are confirmed on site. This is a field estimate, not a stamped design or a permit set.
This is a field estimate from CablingQuote (beta). It is not a stamped RCDD design, engineered drawing, or permit set.